Technical Specifications | |
Other part numbers | 02355SDV (CE8875-24BQ8DQ switch (24*200GE QSFP56, 8*400GE QSFP-DD, Without Fan and Power Modules)) 02355SDX (CE8875-24BQ8DQ switch (24*200GE QSFP56, 8*400GE QSFP-DD, 2*AC Power Modules, 5*Fans, Port-side Intake)) |
Installation Type | Cabinet installation |
Depth [mm] | 420.0 mm |
Chassis height [U] | 1 |
Wide [mm] | 442.0 mm |
Height [mm] | 43.6 mm |
Weight with packaging [kg(lb)] | 9.71 kg (21.41 lb) |
Weight without packaging [kg(lb)] | 6.74 kg (14.86 lb), excluding optical modules, power modules, and fan modules |
Maximum power consumption [W] | 522 W (100% traffic load, short-distance optical modules on 24 x 200GE + 8 x 400GE ports, normal temperature, dual AC power modules) 770 W (100% traffic load, long-distance optical modules on 24 x 200GE + 8 x 400GE ports, high temperature, dual AC power modules) |
Typical power consumption [W] | 291 W (100% traffic load, copper cables on 12 x 200GE + 4 x 400GE ports, normal temperature, dual AC power modules) 382 W (100% traffic load, short-distance optical modules on 12 x 200GE + 4 x 400GE ports, normal temperature, dual AC power modules) |
Static power consumption [W] | 247 W |
Heat dissipation mode | Air cooling |
Maximum heat dissipation [BTU/hour] | - 1781 BTU/hour (100% traffic load, short-distance optical modules on 24 x 200GE + 8 x 400GE ports, normal temperature, dual AC power modules) - 2627 BTU/hour (100% traffic load, long-distance optical modules on 24 x 200GE + 8 x 400GE ports, high temperature, dual AC power modules) |
Typical heat dissipation [BTU/hour] | - 993 BTU/hour (100% traffic load, copper cables on 12 x 200GE + 4 x 400GE ports, normal temperature, dual AC power modules) - 1303 BTU/hour (100% traffic load, short-distance optical modules on 12 x 200GE + 4 x 400GE ports, normal temperature, dual AC power modules) |
Static heat dissipation [BTU/hour] | 843 BTU/hour |
Power supply mode | AC,DC,HVDC |
Rated input voltage [V] | - 1200 W AC&240 V DC power module: 100 V AC to 240 V AC, 50/60 Hz; 240 V DC - 1200 W DC power module: -48 V DC to -60 V DC; +48 V DC |
Input voltage range [V] | - 1200 W AC&240 V DC power module: AC: 90 V AC to 290 V AC, 45 Hz to 65 Hz; DC: 190 V DC to 290 V DC - 1200 W DC power module: -38.4 V DC to -72 V DC; +38.4 V DC to +57 V DC |
Maximum input current [A] | - 1200 W AC&240 V DC power module: 10 A (100 V AC to 130 V AC); 8 A (200 V AC to 240 V AC); 8 A (240 V DC) - 1200 W DC power module: 38 A (-48 V DC to -60 V DC); 38 A (+48 V DC) |
Rated output power [W] | - 1200 W AC&240 V DC power module: 1200 W - 1200 W DC power module: 1200 W |
Memory | DRAM: 8 GB |
NOR Flash | 64 MB |
SSD Flash | 4GB SSD |
USB | It can be used for log backup and USB-based deployment. This function is reserved. |
Console port | RJ45 |
Downlink Service interface | 24 x 200G QSFP56 |
Uplink Service interface | 8 x 400G QSFP-DD |
Service port supporting the stack function | Reserved function. This function is not enabled. |
RTC | Supported |
Switching capacity [bps,bit/s] | To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel. |
Redundant fans | The device supports 4+1 backup of fan modules that work in hot standby mode. The system can operate normally for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately. |
Redundant power supply | 1+1 backup |
Number of power modules | 2 |
Power supply surge protection | AC: 6 kV in common mode and 6 kV in differential mode DC: 4 kV in common mode and 2 kV in differential mode HVDC: 4 kV in common mode and 2 kV in differential mode |
Types of fans | Pluggable |
Number of fans | 5 |
Airflow direction | Port-side air intake or port-side air exhaust, depending on the fan modules and power modules that are used. The fan modules and power modules must have the same airflow direction. |
Storage temperature [°C(°F)] | -40ºC to +70ºC (-40°F to +158°F) |
Long-term operating temperature [°C(°F)] | 0°C to 40°C (32°F to 104°F) at an altitude of 0-1800 m (0-5906 ft.) Note: When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage relative humidity [RH] | 5% to 95% RH, non-condensing |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Storage altitude [m(ft.)] | ≤ 5000 m (16404 ft.) |
Long-term operating altitude [m(ft.)] | ≤ 5000 m (16404 ft.) |
MTBF [year] | 34.22 years |
MTTR [hour] | 1.5 hours |
Noise at high temperature (40°C, sound pressure) | - Front-to-back airflow: 76.2 dB(A) on average; maximum: 79 dB(A) - Back-to-front airflow: 73.1 dB(A) on average; maximum: 79.2 dB(A) |
Noise at normal temperature (27°C, sound pressure) | - Front-to-back airflow: 50.9 dB(A) on average; maximum: 53.8 dB(A) - Back-to-front airflow: 50.8 dB(A) on average; maximum: 54.6 dB(A) |
Availability | 0.999994996 |
Why you choose TELEFLY be one of your partner?
Q1 . What your MOQ?
A1 .1 pcs is ok,whatever how many you need,and we will also give you the best service.
Q2.What certification did you get?
A2 : Our product strictly operate the ISO9001:2008 quality control system and we passed the CE,FCC,ROHS and SGS test,you can trust us.
Q3 :What about your package and delivery,will it broke during shipping?
A3:You don't need to worry about the package,we will use shockproof case for delivering.
Q4.What your common delivery way?
A4:By air, by sea or express(UPS,DHL,Fedex,TNT,EMS...)We will make a perfect delivery plan for you.
Q5.Tell me some detail about warrant time.
A5:We give you the promise if any question during 1 year and not cause by human factors,we will fix it.